{"id":60254,"date":"2025-09-26T10:59:25","date_gmt":"2025-09-26T10:59:25","guid":{"rendered":"https:\/\/becolve.com\/blog\/deconstructing-iec-62443\/"},"modified":"2025-09-26T10:59:25","modified_gmt":"2025-09-26T10:59:25","slug":"deconstructing-iec-62443","status":"publish","type":"blog","link":"https:\/\/becolve.com\/en\/blog\/deconstructing-iec-62443\/","title":{"rendered":"Deconstructing IEC 62443"},"content":{"rendered":"<p class=\"p1\">The <strong>Industry 4.0<\/strong> and <strong>IoT<\/strong> paradigm offers ICS companies many opportunities but also cybersecurity threats. Industrial and critical infrastructure environments must prepare for the growing number of cyberattacks to avoid problems with quality, safety of people\/environment, or decreased productivity. <\/p>\n<p class=\"p1\">The <strong>IEC 62443<\/strong> is a set of standards to offer a <strong>systematic approach to industrial cybersecurity<\/strong>: from risk auditing to operations.<\/p>\n<p class=\"p1\">Using the techniques explained in IEC 62443, <strong>security managers<\/strong> can address the risks for each system and decide how to act accordingly.<\/p>\n<p class=\"p1\">In this post, we will explain what the <strong>main concepts of the standard<\/strong> are that we will use as a basis to build, in later entries, a <strong>reference architecture for Wonderware.<\/strong><\/p>\n<h2 class=\"p2\"><b>IEC62443 Structure<\/b><\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-28804 aligncenter\" src=\"https:\/\/becolve.com\/wp-content\/uploads\/2023\/04\/MKT-ICY-SERVICES-1-Post-IEC62443-1-e1586875071144.gif\" alt=\"\" width=\"900\" height=\"543\"><\/p>\n<p class=\"p1\">The set of <strong>documents<\/strong> that are part of IEC62443 are classified into <strong>4 categories:<\/strong><\/p>\n<ol class=\"ol1\">\n<li class=\"li1\"><strong>General:<\/strong> Fundamental concepts, reference models, and terminology<\/li>\n<li class=\"li1\"><strong>Policies and procedures:<\/strong> A guide is detailed to build and maintain a cybersecurity management program and reinforces the importance of having policies.<\/li>\n<li class=\"li1\"><strong>System:<\/strong> Protection technologies and requirements to achieve a certain level of security.<\/li>\n<li class=\"li1\"><strong>Components:<\/strong> Technical cybersecurity requirements in the product development lifecycle.<\/li>\n<\/ol>\n<h2 class=\"p5\"><b>Objectives<\/b><\/h2>\n<p class=\"p1\">The main objective of the standard is to <strong>reduce the risks that may affect the assets<\/strong> that generate value in an industrial or critical infrastructure environment.<\/p>\n<p class=\"p1\">To achieve this objective, it must be understood that:<\/p>\n<ul class=\"ul1\">\n<li class=\"li1\"><strong>Asset<\/strong> = physical (equipment, machines), logical (information), people (know-how) whose existence and operation add value to the process. To assess the impact of a threat, it must be assessed both quantitatively and qualitatively. <\/li>\n<li class=\"li1\"><strong>Risk<\/strong> = the probability that a threat will occur due to the existence of vulnerabilities that allow it, producing a negative effect on the assets of the process<\/li>\n<li class=\"li1\"><strong>Threat<\/strong> = event or action that is harmful to an asset or system.<\/li>\n<li class=\"li1\"><strong>Vulnerability<\/strong> = inherent weakness of an asset or system that can be exploited, intentionally or not, for a threat to be carried out.<\/li>\n<li class=\"li1\"><strong>Countermeasure<\/strong> = action or system intended to eliminate vulnerabilities or the effects of associated threats. They can be technical (authentication, IDS, anti-malware, &#8230;), administrative (policies, procedures) or physical (barriers, doors, &#8230;) <\/li>\n<\/ul>\n<h2 class=\"p5\"><b>Basic Concepts<\/b><\/h2>\n<p class=\"p1\">The <strong>basic security procedure<\/strong> of an industrial infrastructure, according to IEC 62443, consists (in a summarized and simplified way) of the following steps:<\/p>\n<p class=\"p1\"><strong>1. Identify the zones, conduits, and channels.<\/strong><\/p>\n<ul>\n<li><strong>Zone<\/strong><\/li>\n<\/ul>\n<p>Logical grouping of assets that share the same security requirements. They can have subzones that inherit their characteristics and allow developing in-depth defense strategies. <\/p>\n<ul>\n<li><strong>Conduit<\/strong><\/li>\n<\/ul>\n<p>Logical grouping of assets that share the same security requirements. They can have subzones that inherit their characteristics and allow developing in-depth defense strategies. <\/p>\n<ul>\n<li><strong>Channel<\/strong><\/li>\n<\/ul>\n<p>Logical grouping of assets that share the same security requirements. They can have subzones that inherit their characteristics and allow developing in-depth defense strategies. <\/p>\n<p class=\"p1\"><strong>2. Identify the desired level of protection for each zone and conduit.<\/strong><\/p>\n<p>IEC 62443 indicates that for each zone, conduit, it must be decided <strong>what is the desired level of protection<\/strong>  for each of the fundamental protection requirements.<\/p>\n<p>The <strong>security levels<\/strong> defined in the standard are:<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-28795 aligncenter\" src=\"https:\/\/becolve.com\/wp-content\/uploads\/2023\/04\/Captura-de-pantalla-2020-04-14-a-las-14.41.40.png\" alt=\"\" width=\"647\" height=\"361\">The <strong>fundamental security requirements<\/strong> defined by IEC 62443 are:<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-28797 size-full aligncenter\" src=\"https:\/\/becolve.com\/wp-content\/uploads\/2023\/04\/Captura-de-pantalla-2020-04-14-a-las-14.32.34.png\" alt=\"\" width=\"647\" height=\"472\"><\/p>\n<p class=\"p1\">Therefore, <strong>the desired security level<\/strong> is represented by:<\/p>\n<div class=\"page\" title=\"Page 3\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p><em>SL-T(Zone) = {AC UC DI DC RDF TRE RA}<\/em><\/p>\n<div class=\"page\" title=\"Page 3\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>where each element of the vector is a number from 1 to 4.<\/p>\n<div class=\"page\" title=\"Page 4\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p><strong>3. Evaluate the current level of protection<\/strong><\/p>\n<p>Similarly, for each of the zones and\/or conduits, the security level will be evaluated based on whether the system and improvement requirements of each of the fundamental requirements mentioned above are met.<\/p>\n<\/div>\n<\/div>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>In this way:<\/p>\n<p><em>SL-T(Zone) = {AC UC DI DC RDF TRE RA}<\/em><\/p>\n<p><strong>4. Apply necessary countermeasures so that <em>SL-A (Zone) &gt;= SL-T (Zone)<\/em><\/strong><\/p>\n<p>&nbsp;<\/p>\n<div class=\"page\" title=\"Page 4\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<h2><strong>Reference models<\/strong><\/h2>\n<div class=\"page\" title=\"Page 4\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>In the <strong>different models shown by IEC 62443<\/strong>, it can give us an idea of how to define the zones in our infrastructure, although as can be seen, the size of the zones is arbitrary, they can be created as large or as small as deemed appropriate according to the characteristics of each one.<\/p>\n<p>It is recommended to <strong>maintain a degree of low \u201cparanoia\u201d at the beginning and create subzones<\/strong> as the iterative improvement process is executed.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-28807\" src=\"https:\/\/becolve.com\/wp-content\/uploads\/2023\/04\/ejemplo.jpg\" alt=\"example critical infrastructure\" width=\"900\" height=\"749\"><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<h2><strong>References<\/strong><\/h2>\n<div class=\"page\" title=\"Page 5\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<ul>\n<li><a href=\"https:\/\/www.isa.org\/intech\/201810standards\/\" target=\"_blank\" rel=\"noopener noreferrer\">https:\/\/www.isa.org\/intech\/201810standards\/<\/a><\/li>\n<li><a href=\"https:\/\/www.isa.org\/standards-and-publications\/isa-standards\/find-isa-standards-in-numerical-order\/\" target=\"_blank\" rel=\"noopener noreferrer\">https:\/\/www.isa.org\/standards-and-publications\/isa-standards\/find-isa-standards-in-numerical-order\/<\/a><\/li>\n<li><a href=\"https:\/\/webstore.iec.ch\/preview\/info_iec62443-1-1%7Bed1.0%7Den.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">https:\/\/webstore.iec.ch\/preview\/info_iec62443-1-1%7Bed1.0%7Den.pdf<\/a><\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>First post in a series of three on the IEC 62443 standard<\/p>\n","protected":false},"author":31,"featured_media":60259,"menu_order":0,"template":"","categories":[1371],"tags":[1415],"arquitectura":[1839],"area":[],"sector":[],"experto":[1396],"weborigen":[157],"productos-tax":[],"soluciones-tax":[],"marcas-tax":[],"coauthors":[],"class_list":["post-60254","blog","type-blog","status-publish","has-post-thumbnail","hentry","category-cybersecurity","tag-iec-62443","arquitectura-industrial-cybersecurity","experto-industrial-cybersecurity-total-availability","weborigen-ciberseguridadlogitek-com"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Deconstructing IEC 62443<\/title>\n<meta name=\"description\" content=\"What are the main concepts of the IEC 62443 standard that we will use as a basis to build a reference architecture for Wonderware.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/becolve.com\/en\/blog\/deconstructing-iec-62443\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Deconstructing IEC 62443\" \/>\n<meta property=\"og:description\" content=\"What are the main concepts of the IEC 62443 standard that we will use as a basis to build a reference architecture for Wonderware.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/becolve.com\/en\/blog\/deconstructing-iec-62443\/\" \/>\n<meta property=\"og:site_name\" content=\"Becolve Digital\" \/>\n<meta property=\"og:image\" content=\"https:\/\/becolve.com\/wp-content\/uploads\/2023\/04\/IEC-62443.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"400\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@Logitek_es\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n\t<meta name=\"twitter:label2\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data2\" content=\"Becolve Digital\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/becolve.com\\\/en\\\/blog\\\/deconstructing-iec-62443\\\/\",\"url\":\"https:\\\/\\\/becolve.com\\\/en\\\/blog\\\/deconstructing-iec-62443\\\/\",\"name\":\"Deconstructing IEC 62443\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/becolve.com\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/becolve.com\\\/en\\\/blog\\\/deconstructing-iec-62443\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/becolve.com\\\/en\\\/blog\\\/deconstructing-iec-62443\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/becolve.com\\\/wp-content\\\/uploads\\\/2023\\\/04\\\/IEC-62443.jpg\",\"datePublished\":\"2025-09-26T10:59:25+00:00\",\"description\":\"What are the main concepts of the IEC 62443 standard that we will use as a basis to build a reference architecture for Wonderware.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/becolve.com\\\/en\\\/blog\\\/deconstructing-iec-62443\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/becolve.com\\\/en\\\/blog\\\/deconstructing-iec-62443\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/becolve.com\\\/en\\\/blog\\\/deconstructing-iec-62443\\\/#primaryimage\",\"url\":\"https:\\\/\\\/becolve.com\\\/wp-content\\\/uploads\\\/2023\\\/04\\\/IEC-62443.jpg\",\"contentUrl\":\"https:\\\/\\\/becolve.com\\\/wp-content\\\/uploads\\\/2023\\\/04\\\/IEC-62443.jpg\",\"width\":800,\"height\":400},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/becolve.com\\\/en\\\/blog\\\/deconstructing-iec-62443\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/becolve.com\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Blog Items\",\"item\":\"https:\\\/\\\/becolve.com\\\/en\\\/blog\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Deconstructing IEC 62443\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/becolve.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/becolve.com\\\/en\\\/\",\"name\":\"Becolve Digital\",\"description\":\"Transformaci\u00f3n digital en industria e infraestructuras\",\"publisher\":{\"@id\":\"https:\\\/\\\/becolve.com\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/becolve.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/becolve.com\\\/en\\\/#organization\",\"name\":\"Becolve Digital\",\"url\":\"https:\\\/\\\/becolve.com\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/becolve.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/becolve.com\\\/wp-content\\\/uploads\\\/2023\\\/04\\\/becolve-logo-h-black_200.png\",\"contentUrl\":\"https:\\\/\\\/becolve.com\\\/wp-content\\\/uploads\\\/2023\\\/04\\\/becolve-logo-h-black_200.png\",\"width\":200,\"height\":64,\"caption\":\"Becolve Digital\"},\"image\":{\"@id\":\"https:\\\/\\\/becolve.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/x.com\\\/Logitek_es\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/becolve-digital\\\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Deconstructing IEC 62443","description":"What are the main concepts of the IEC 62443 standard that we will use as a basis to build a reference architecture for Wonderware.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/becolve.com\/en\/blog\/deconstructing-iec-62443\/","og_locale":"en_US","og_type":"article","og_title":"Deconstructing IEC 62443","og_description":"What are the main concepts of the IEC 62443 standard that we will use as a basis to build a reference architecture for Wonderware.","og_url":"https:\/\/becolve.com\/en\/blog\/deconstructing-iec-62443\/","og_site_name":"Becolve Digital","og_image":[{"width":800,"height":400,"url":"https:\/\/becolve.com\/wp-content\/uploads\/2023\/04\/IEC-62443.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_site":"@Logitek_es","twitter_misc":{"Est. reading time":"3 minutes","Written by":"Becolve Digital"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/becolve.com\/en\/blog\/deconstructing-iec-62443\/","url":"https:\/\/becolve.com\/en\/blog\/deconstructing-iec-62443\/","name":"Deconstructing IEC 62443","isPartOf":{"@id":"https:\/\/becolve.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/becolve.com\/en\/blog\/deconstructing-iec-62443\/#primaryimage"},"image":{"@id":"https:\/\/becolve.com\/en\/blog\/deconstructing-iec-62443\/#primaryimage"},"thumbnailUrl":"https:\/\/becolve.com\/wp-content\/uploads\/2023\/04\/IEC-62443.jpg","datePublished":"2025-09-26T10:59:25+00:00","description":"What are the main concepts of the IEC 62443 standard that we will use as a basis to build a reference architecture for Wonderware.","breadcrumb":{"@id":"https:\/\/becolve.com\/en\/blog\/deconstructing-iec-62443\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/becolve.com\/en\/blog\/deconstructing-iec-62443\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/becolve.com\/en\/blog\/deconstructing-iec-62443\/#primaryimage","url":"https:\/\/becolve.com\/wp-content\/uploads\/2023\/04\/IEC-62443.jpg","contentUrl":"https:\/\/becolve.com\/wp-content\/uploads\/2023\/04\/IEC-62443.jpg","width":800,"height":400},{"@type":"BreadcrumbList","@id":"https:\/\/becolve.com\/en\/blog\/deconstructing-iec-62443\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/becolve.com\/en\/"},{"@type":"ListItem","position":2,"name":"Blog Items","item":"https:\/\/becolve.com\/en\/blog\/"},{"@type":"ListItem","position":3,"name":"Deconstructing IEC 62443"}]},{"@type":"WebSite","@id":"https:\/\/becolve.com\/en\/#website","url":"https:\/\/becolve.com\/en\/","name":"Becolve Digital","description":"Transformaci\u00f3n digital en industria e infraestructuras","publisher":{"@id":"https:\/\/becolve.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/becolve.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/becolve.com\/en\/#organization","name":"Becolve Digital","url":"https:\/\/becolve.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/becolve.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/becolve.com\/wp-content\/uploads\/2023\/04\/becolve-logo-h-black_200.png","contentUrl":"https:\/\/becolve.com\/wp-content\/uploads\/2023\/04\/becolve-logo-h-black_200.png","width":200,"height":64,"caption":"Becolve Digital"},"image":{"@id":"https:\/\/becolve.com\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/x.com\/Logitek_es","https:\/\/www.linkedin.com\/company\/becolve-digital\/"]}]}},"_links":{"self":[{"href":"https:\/\/becolve.com\/en\/wp-json\/wp\/v2\/blog\/60254","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/becolve.com\/en\/wp-json\/wp\/v2\/blog"}],"about":[{"href":"https:\/\/becolve.com\/en\/wp-json\/wp\/v2\/types\/blog"}],"author":[{"embeddable":true,"href":"https:\/\/becolve.com\/en\/wp-json\/wp\/v2\/users\/31"}],"version-history":[{"count":0,"href":"https:\/\/becolve.com\/en\/wp-json\/wp\/v2\/blog\/60254\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/becolve.com\/en\/wp-json\/wp\/v2\/media\/60259"}],"wp:attachment":[{"href":"https:\/\/becolve.com\/en\/wp-json\/wp\/v2\/media?parent=60254"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/becolve.com\/en\/wp-json\/wp\/v2\/categories?post=60254"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/becolve.com\/en\/wp-json\/wp\/v2\/tags?post=60254"},{"taxonomy":"arquitectura","embeddable":true,"href":"https:\/\/becolve.com\/en\/wp-json\/wp\/v2\/arquitectura?post=60254"},{"taxonomy":"area","embeddable":true,"href":"https:\/\/becolve.com\/en\/wp-json\/wp\/v2\/area?post=60254"},{"taxonomy":"sector","embeddable":true,"href":"https:\/\/becolve.com\/en\/wp-json\/wp\/v2\/sector?post=60254"},{"taxonomy":"experto","embeddable":true,"href":"https:\/\/becolve.com\/en\/wp-json\/wp\/v2\/experto?post=60254"},{"taxonomy":"weborigen","embeddable":true,"href":"https:\/\/becolve.com\/en\/wp-json\/wp\/v2\/weborigen?post=60254"},{"taxonomy":"productos-tax","embeddable":true,"href":"https:\/\/becolve.com\/en\/wp-json\/wp\/v2\/productos-tax?post=60254"},{"taxonomy":"soluciones-tax","embeddable":true,"href":"https:\/\/becolve.com\/en\/wp-json\/wp\/v2\/soluciones-tax?post=60254"},{"taxonomy":"marcas-tax","embeddable":true,"href":"https:\/\/becolve.com\/en\/wp-json\/wp\/v2\/marcas-tax?post=60254"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/becolve.com\/en\/wp-json\/wp\/v2\/coauthors?post=60254"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}