{"id":48047,"date":"2025-09-17T17:58:33","date_gmt":"2025-09-17T17:58:33","guid":{"rendered":"https:\/\/becolve.com\/blog\/opc-router-como-complemento-aos-scadas\/"},"modified":"2025-09-17T17:58:55","modified_gmt":"2025-09-17T17:58:55","slug":"opc-router-como-complemento-aos-scadas","status":"publish","type":"blog","link":"https:\/\/becolve.com\/pt-pt\/blog\/opc-router-como-complemento-aos-scadas\/","title":{"rendered":"OPC Router como complemento aos SCADAs."},"content":{"rendered":"<p>[et_pb_section fb_built=&#8221;1&#8243; _builder_version=&#8221;4.16&#8243; global_colors_info=&#8221;{}&#8221;][et_pb_row _builder_version=&#8221;4.16&#8243; background_size=&#8221;initial&#8221; background_position=&#8221;top_left&#8221; background_repeat=&#8221;repeat&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;4.16&#8243; custom_padding=&#8221;|||&#8221; global_colors_info=&#8221;{}&#8221; custom_padding__hover=&#8221;|||&#8221;][et_pb_text _builder_version=&#8221;4.16&#8243; background_size=&#8221;initial&#8221; background_position=&#8221;top_left&#8221; background_repeat=&#8221;repeat&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<p>\u00c9 evidente que <strong>as fun\u00e7\u00f5es de um SCADA<\/strong> evolu\u00edram com o passar dos anos. Se h\u00e1 algum tempo se entendia como SCADA aquele HMI que supervisionava alguns PLCs e que permitia programar-lhe certa l\u00f3gica, atualmente um SCADA \u00e9 mais uma plataforma de supervis\u00e3o, controlo e planeamento de toda uma instala\u00e7\u00e3o industrial ou uma infraestrutura. A sua fun\u00e7\u00e3o vai muito mais al\u00e9m de s\u00f3 mostrar por ecr\u00e3 o estado do processo a supervisionar, mas tamb\u00e9m <strong>pode incluir fun\u00e7\u00f5es de anal\u00edtica de dados, visualiza\u00e7\u00e3o WEB, sistemas MES<\/strong>, gest\u00e3o de acessos ou visualiza\u00e7\u00e3o de c\u00e2maras.  <\/p>\n<p>Em resumo, <strong>a evolu\u00e7\u00e3o dos SCADAs permitiu-lhes gerir mais processos da instala\u00e7\u00e3o<\/strong>. O problema \u00e9 que ainda se pretende incorporar ainda mais tarefas e nem sempre est\u00e3o preparados para elas. Sem d\u00favida, os SCADAs v\u00e3o no caminho de acabar por ser o gestor e \u00e1rbitro dos diferentes sistemas que controlam, monitorizam, rastreiam e supervisionam o processo ou facilitam o trabalho dos trabalhadores.  <\/p>\n<p>A quest\u00e3o \u00e9 que os <strong>SCADAs,<\/strong> maioritariamente, em tema de comunica\u00e7\u00f5es ainda est\u00e3o <strong>ancorados \u00e0 sua origem, a automatiza\u00e7\u00e3o industrial.<\/strong> Isso nota-se em que os seus drivers de comunica\u00e7\u00e3o s\u00f3 costumam ser do tipo OPC, Modbus ou para PLCs Siemens ou similares. No m\u00e1ximo, os mais avan\u00e7ados permitem integrar-se com bases de dados SQL ou permitem incorporar bibliotecas .NET para que o utilizador\/engenharia integrem os seus pr\u00f3prios desenvolvimentos \u00e0 medida. Em qualquer caso, <strong>n\u00e3o incorporam drivers que facilitem trabalhar com outros sistemas<\/strong> presentes na instala\u00e7\u00e3o.<\/p>\n<p>Al\u00e9m disso, outro problema presente na integra\u00e7\u00e3o do SCADA com outras ferramentas de software \u00e9 que os SCADAs <strong>foram concebidos para ser o recetor final dos dados<\/strong>, ou seja, d\u00e3o-se muito bem a adquirir dados de diferentes fontes, mas bastante pior a servir dados para outros sistemas. Para o fazer, o mais comum \u2013 e \u00fanico caminho normalmente \u2013 \u00e9 <strong>utiliz\u00e1-lo como OPC Server<\/strong>, onde nas suas tags escreveremos aquilo que pretendemos enviar-lhe. <\/p>\n<p>Este \u00e9 o cen\u00e1rio atual e perante esses desafios \u00e9 onde o OPC Router se apresenta como uma ferramenta muito <strong>\u00fatil para facilitar a comunica\u00e7\u00e3o entre o SCADA e outros softwares<\/strong>, como podem ser BMS, softwares de rastreabilidade, de qualidade, de manuten\u00e7\u00e3o, o ERP, impressoras, etc.<\/p>\n<p>A seguir, apresentamos <strong>alguns exemplos de como o OPC Router pode complementar um SCADA<\/strong> e fazer com que este possa gerir ainda mais fun\u00e7\u00f5es dentro de uma instala\u00e7\u00e3o.<\/p>\n<p>&nbsp;<\/p>\n<h3><strong><span style=\"color: #ffcc00;\">I <\/span>Integrar no SCADA sistemas BMS<\/strong><\/h3>\n<p>Que no SCADA se monitorizem os sistemas HVAC ou controladores de elevadores, por exemplo, n\u00e3o \u00e9 algo invulgar, mas cada vez mais se tenta tamb\u00e9m que este gerir o conforto dos espa\u00e7os de trabalho (temperaturas, humidades, persianas e barreiras autom\u00e1ticas, estacionamento, \u2026) ou fun\u00e7\u00f5es mais semelhantes \u00e0 dom\u00f3tica que \u00e0 automatiza\u00e7\u00e3o de processos industriais. Perante esse desafio, o OPC Router pode ajudar o SCADA a integrar-se com as ferramentas independentes que gerem cada uma destas fun\u00e7\u00f5es.<br \/>S\u00f3 para dar um exemplo concreto, a seguir mostra-se um exemplo onde o OPC Router \u00e9 capaz de monitorizar a que horas uma sala est\u00e1 reservada no Calendar do Outlook para a aclimatar com anterioridade e apagar essa climatiza\u00e7\u00e3o quando n\u00e3o est\u00e1 a ser utilizada. <\/p>\n<p>&nbsp;<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-large wp-image-3214\" src=\"https:\/\/becolve.com\/wp-content\/uploads\/2023\/04\/integracion-1024x518.png\" alt=\"integra\u00e7\u00e3o SCADA em BMS\" width=\"1024\" height=\"518\"><\/p>\n<p>&nbsp;<\/p>\n<h3><strong><span style=\"color: #ffcc00;\">I<\/span> Integrar no SCADA informa\u00e7\u00e3o do GMAO.<\/strong><\/h3>\n<p>Os GMAOs, APMs e sistemas de gest\u00e3o de ativos em geral t\u00eam um problema similar aos SCADAs no que toca a que est\u00e3o pensados em receber informa\u00e7\u00e3o, n\u00e3o em servi-la a outras ferramentas. \u00c9 por isso que <strong>nem sempre \u00e9 simples construir pontes entre os dois mundos<\/strong>, o da supervis\u00e3o\/controlo com o da manuten\u00e7\u00e3o. <\/p>\n<p>Pela nossa experi\u00eancia, e sempre dependendo do GMAO, o mais simples \u00e9 <strong>adquirir a informa\u00e7\u00e3o do SCADA mediante OPC<\/strong> \u2013 o SCADA atuando como OPC DA\/UA Server \u2013 e enviar a informa\u00e7\u00e3o para uma base de dados com a qual o GMAO possa trabalhar.<\/p>\n<p><strong>Se o fluxo da informa\u00e7\u00e3o deve ser o contr\u00e1rio<\/strong> \u2013 o GMAO serve informa\u00e7\u00e3o ao SCADA -, o mais simples \u00e9 atacar a base de dados na qual se baseia o GMAO ou, se for dos mais avan\u00e7ados, mediante servi\u00e7os SOAP.<\/p>\n<p>&nbsp;<\/p>\n<h3><strong><span style=\"color: #ffcc00;\">I<\/span> Integrar o SCADA com o ERP.<\/strong><\/h3>\n<p>Ainda que o tenhamos tratado extensamente <strong><a href=\"https:\/\/logitek.es\/opc-router-ebook\/\" target=\"_blank\" rel=\"noopener\">no nosso ebook<\/a>,<\/strong> \u00e9 evidente que este \u00e9 um dos casos para o qual mais se utiliza o OPC Router<strong>. O seu plugin para conectar com SAP ou com outros ERPs<\/strong> permite solucionar essa lacuna de maneira simples sem necessidade de desenvolvimentos \u00e0 medida.<\/p>\n<p>&nbsp;<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-3216\" src=\"https:\/\/becolve.com\/wp-content\/uploads\/2023\/04\/integrar.png\" alt=\"integrar SCADA com GRP\" width=\"916\" height=\"462\"><\/p>\n<p>&nbsp;<\/p>\n<h3><strong><span style=\"color: #ffcc00;\">I<\/span> Integrar o SCADA com impressoras ou RFIDs.<\/strong><\/h3>\n<p>Ainda que as <strong>impressoras ou leitores RFID sejam equipamento industrial muito utilizado<\/strong>, \u00e9 bastante invulgar que os SCADAs ou, inclusive, os OPC servers de mercado tenham drivers concretos para comunicar com estes dispositivos. Como comunico ent\u00e3o o meu SCADA com as minhas impressoras Zebra? Para solucionar este problema, uma vez mais, ganha valor o OPC Router como ponte entre ambos.  <\/p>\n<p>&nbsp;<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-3218\" src=\"https:\/\/becolve.com\/wp-content\/uploads\/2023\/04\/impresoras.png\" alt=\"integra\u00e7\u00e3o SCADA com impressoras\" width=\"885\" height=\"468\"><\/p>\n<p>&nbsp;<\/p>\n<p>Isto s\u00e3o s\u00f3 alguns exemplos dos muitos que podemos encontrar onde <strong>o OPC Router complementa as comunica\u00e7\u00f5es do SCADA<\/strong> para que este ainda gerir mais fun\u00e7\u00f5es. \u00c9 muito importante destacar que, ainda que o OPC Router permita fun\u00e7\u00f5es de scripting, n\u00e3o \u00e9 um substituto do SCADA. Deve ser este \u00faltimo sempre quem leve a cabo o controlo e execu\u00e7\u00e3o da l\u00f3gica.    <strong>O OPC Router \u00e9 o complemento, n\u00e3o a solu\u00e7\u00e3o inteira.<\/strong><\/p>\n<p>Se lhe interessa saber de mais exemplos ou acredita que lhe pode ser de ajuda nestes ou outros projetos que tem pela frente, entre em contacto connosco e consulte-nos!<\/p>\n<p>[\/et_pb_text][et_pb_button button_url=&#8221;https:\/\/logitek.es\/opc_router\/&#8221; button_text=&#8221;Conhe\u00e7a o OPC Router a fundo&#8221; button_alignment=&#8221;center&#8221; _builder_version=&#8221;4.16&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_button][\/et_pb_column][\/et_pb_row][\/et_pb_section]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Apresentamos alguns exemplos de como o OPC Router pode complementar um SCADA e fazer com que este possa gerir ainda mais fun\u00e7\u00f5es dentro de uma instala\u00e7\u00e3o.<\/p>\n","protected":false},"author":31,"featured_media":48051,"menu_order":0,"template":"","categories":[977],"tags":[1013,1018],"arquitectura":[1842],"area":[],"sector":[],"experto":[204],"weborigen":[136],"productos-tax":[87],"soluciones-tax":[213],"marcas-tax":[],"coauthors":[],"class_list":["post-48047","blog","type-blog","status-publish","has-post-thumbnail","hentry","category-comunicacoes","tag-erp","tag-gmao","arquitectura-comunicacoes-industriais","experto-comunicacoes-industriais","weborigen-comunicacionesindustiraleslogitek-com","productos-tax-opc-router","soluciones-tax-communication-hub-pt-pt"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>OPC Router como complemento ao SCADA<\/title>\n<meta name=\"description\" content=\"Apresentamos alguns exemplos de como o OPC Router pode complementar um SCADA e fazer com que este possa gerir ainda mais fun\u00e7\u00f5es dentro de uma instala\u00e7\u00e3o.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/becolve.com\/pt-pt\/blog\/opc-router-como-complemento-aos-scadas\/\" \/>\n<meta property=\"og:locale\" content=\"pt_PT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"OPC Router como complemento ao SCADA\" \/>\n<meta property=\"og:description\" content=\"Apresentamos alguns exemplos de como o OPC Router pode complementar um SCADA e fazer com que este possa gerir ainda mais fun\u00e7\u00f5es dentro de uma instala\u00e7\u00e3o.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/becolve.com\/pt-pt\/blog\/opc-router-como-complemento-aos-scadas\/\" \/>\n<meta property=\"og:site_name\" content=\"Becolve Digital\" \/>\n<meta property=\"article:modified_time\" content=\"2025-09-17T17:58:55+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/becolve.com\/wp-content\/uploads\/2023\/04\/OPC_ROUTER.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"400\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@Logitek_es\" \/>\n<meta name=\"twitter:label1\" content=\"Tempo estimado de leitura\" \/>\n\t<meta name=\"twitter:data1\" content=\"5 minutos\" \/>\n\t<meta name=\"twitter:label2\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data2\" content=\"Becolve Digital\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/becolve.com\\\/pt-pt\\\/blog\\\/opc-router-como-complemento-aos-scadas\\\/\",\"url\":\"https:\\\/\\\/becolve.com\\\/pt-pt\\\/blog\\\/opc-router-como-complemento-aos-scadas\\\/\",\"name\":\"OPC Router como complemento ao SCADA\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/becolve.com\\\/pt-pt\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/becolve.com\\\/pt-pt\\\/blog\\\/opc-router-como-complemento-aos-scadas\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/becolve.com\\\/pt-pt\\\/blog\\\/opc-router-como-complemento-aos-scadas\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/becolve.com\\\/wp-content\\\/uploads\\\/2023\\\/04\\\/OPC_ROUTER.jpg\",\"datePublished\":\"2025-09-17T17:58:33+00:00\",\"dateModified\":\"2025-09-17T17:58:55+00:00\",\"description\":\"Apresentamos alguns exemplos de como o OPC Router pode complementar um SCADA e fazer com que este possa gerir ainda mais fun\u00e7\u00f5es dentro de uma instala\u00e7\u00e3o.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/becolve.com\\\/pt-pt\\\/blog\\\/opc-router-como-complemento-aos-scadas\\\/#breadcrumb\"},\"inLanguage\":\"pt-PT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/becolve.com\\\/pt-pt\\\/blog\\\/opc-router-como-complemento-aos-scadas\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-PT\",\"@id\":\"https:\\\/\\\/becolve.com\\\/pt-pt\\\/blog\\\/opc-router-como-complemento-aos-scadas\\\/#primaryimage\",\"url\":\"https:\\\/\\\/becolve.com\\\/wp-content\\\/uploads\\\/2023\\\/04\\\/OPC_ROUTER.jpg\",\"contentUrl\":\"https:\\\/\\\/becolve.com\\\/wp-content\\\/uploads\\\/2023\\\/04\\\/OPC_ROUTER.jpg\",\"width\":800,\"height\":400},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/becolve.com\\\/pt-pt\\\/blog\\\/opc-router-como-complemento-aos-scadas\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/becolve.com\\\/pt-pt\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Blog Items\",\"item\":\"https:\\\/\\\/becolve.com\\\/pt-pt\\\/blog\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"OPC Router como complemento aos SCADAs.\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/becolve.com\\\/pt-pt\\\/#website\",\"url\":\"https:\\\/\\\/becolve.com\\\/pt-pt\\\/\",\"name\":\"Becolve Digital\",\"description\":\"Impulsamos la transformaci\u00f3n digital en la industria e infraestructuras\",\"publisher\":{\"@id\":\"https:\\\/\\\/becolve.com\\\/pt-pt\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/becolve.com\\\/pt-pt\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"pt-PT\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/becolve.com\\\/pt-pt\\\/#organization\",\"name\":\"Becolve Digital\",\"url\":\"https:\\\/\\\/becolve.com\\\/pt-pt\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-PT\",\"@id\":\"https:\\\/\\\/becolve.com\\\/pt-pt\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/becolve.com\\\/wp-content\\\/uploads\\\/2023\\\/04\\\/becolve-logo-h-black_200.png\",\"contentUrl\":\"https:\\\/\\\/becolve.com\\\/wp-content\\\/uploads\\\/2023\\\/04\\\/becolve-logo-h-black_200.png\",\"width\":200,\"height\":64,\"caption\":\"Becolve Digital\"},\"image\":{\"@id\":\"https:\\\/\\\/becolve.com\\\/pt-pt\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/x.com\\\/Logitek_es\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/becolve-digital\\\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"OPC Router como complemento ao SCADA","description":"Apresentamos alguns exemplos de como o OPC Router pode complementar um SCADA e fazer com que este possa gerir ainda mais fun\u00e7\u00f5es dentro de uma instala\u00e7\u00e3o.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/becolve.com\/pt-pt\/blog\/opc-router-como-complemento-aos-scadas\/","og_locale":"pt_PT","og_type":"article","og_title":"OPC Router como complemento ao SCADA","og_description":"Apresentamos alguns exemplos de como o OPC Router pode complementar um SCADA e fazer com que este possa gerir ainda mais fun\u00e7\u00f5es dentro de uma instala\u00e7\u00e3o.","og_url":"https:\/\/becolve.com\/pt-pt\/blog\/opc-router-como-complemento-aos-scadas\/","og_site_name":"Becolve Digital","article_modified_time":"2025-09-17T17:58:55+00:00","og_image":[{"width":800,"height":400,"url":"https:\/\/becolve.com\/wp-content\/uploads\/2023\/04\/OPC_ROUTER.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_site":"@Logitek_es","twitter_misc":{"Tempo estimado de leitura":"5 minutos","Written by":"Becolve Digital"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/becolve.com\/pt-pt\/blog\/opc-router-como-complemento-aos-scadas\/","url":"https:\/\/becolve.com\/pt-pt\/blog\/opc-router-como-complemento-aos-scadas\/","name":"OPC Router como complemento ao SCADA","isPartOf":{"@id":"https:\/\/becolve.com\/pt-pt\/#website"},"primaryImageOfPage":{"@id":"https:\/\/becolve.com\/pt-pt\/blog\/opc-router-como-complemento-aos-scadas\/#primaryimage"},"image":{"@id":"https:\/\/becolve.com\/pt-pt\/blog\/opc-router-como-complemento-aos-scadas\/#primaryimage"},"thumbnailUrl":"https:\/\/becolve.com\/wp-content\/uploads\/2023\/04\/OPC_ROUTER.jpg","datePublished":"2025-09-17T17:58:33+00:00","dateModified":"2025-09-17T17:58:55+00:00","description":"Apresentamos alguns exemplos de como o OPC Router pode complementar um SCADA e fazer com que este possa gerir ainda mais fun\u00e7\u00f5es dentro de uma instala\u00e7\u00e3o.","breadcrumb":{"@id":"https:\/\/becolve.com\/pt-pt\/blog\/opc-router-como-complemento-aos-scadas\/#breadcrumb"},"inLanguage":"pt-PT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/becolve.com\/pt-pt\/blog\/opc-router-como-complemento-aos-scadas\/"]}]},{"@type":"ImageObject","inLanguage":"pt-PT","@id":"https:\/\/becolve.com\/pt-pt\/blog\/opc-router-como-complemento-aos-scadas\/#primaryimage","url":"https:\/\/becolve.com\/wp-content\/uploads\/2023\/04\/OPC_ROUTER.jpg","contentUrl":"https:\/\/becolve.com\/wp-content\/uploads\/2023\/04\/OPC_ROUTER.jpg","width":800,"height":400},{"@type":"BreadcrumbList","@id":"https:\/\/becolve.com\/pt-pt\/blog\/opc-router-como-complemento-aos-scadas\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/becolve.com\/pt-pt\/"},{"@type":"ListItem","position":2,"name":"Blog Items","item":"https:\/\/becolve.com\/pt-pt\/blog\/"},{"@type":"ListItem","position":3,"name":"OPC Router como complemento aos SCADAs."}]},{"@type":"WebSite","@id":"https:\/\/becolve.com\/pt-pt\/#website","url":"https:\/\/becolve.com\/pt-pt\/","name":"Becolve Digital","description":"Impulsamos la transformaci\u00f3n digital en la industria e infraestructuras","publisher":{"@id":"https:\/\/becolve.com\/pt-pt\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/becolve.com\/pt-pt\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"pt-PT"},{"@type":"Organization","@id":"https:\/\/becolve.com\/pt-pt\/#organization","name":"Becolve Digital","url":"https:\/\/becolve.com\/pt-pt\/","logo":{"@type":"ImageObject","inLanguage":"pt-PT","@id":"https:\/\/becolve.com\/pt-pt\/#\/schema\/logo\/image\/","url":"https:\/\/becolve.com\/wp-content\/uploads\/2023\/04\/becolve-logo-h-black_200.png","contentUrl":"https:\/\/becolve.com\/wp-content\/uploads\/2023\/04\/becolve-logo-h-black_200.png","width":200,"height":64,"caption":"Becolve Digital"},"image":{"@id":"https:\/\/becolve.com\/pt-pt\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/x.com\/Logitek_es","https:\/\/www.linkedin.com\/company\/becolve-digital\/"]}]}},"_links":{"self":[{"href":"https:\/\/becolve.com\/pt-pt\/wp-json\/wp\/v2\/blog\/48047","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/becolve.com\/pt-pt\/wp-json\/wp\/v2\/blog"}],"about":[{"href":"https:\/\/becolve.com\/pt-pt\/wp-json\/wp\/v2\/types\/blog"}],"author":[{"embeddable":true,"href":"https:\/\/becolve.com\/pt-pt\/wp-json\/wp\/v2\/users\/31"}],"version-history":[{"count":0,"href":"https:\/\/becolve.com\/pt-pt\/wp-json\/wp\/v2\/blog\/48047\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/becolve.com\/pt-pt\/wp-json\/wp\/v2\/media\/48051"}],"wp:attachment":[{"href":"https:\/\/becolve.com\/pt-pt\/wp-json\/wp\/v2\/media?parent=48047"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/becolve.com\/pt-pt\/wp-json\/wp\/v2\/categories?post=48047"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/becolve.com\/pt-pt\/wp-json\/wp\/v2\/tags?post=48047"},{"taxonomy":"arquitectura","embeddable":true,"href":"https:\/\/becolve.com\/pt-pt\/wp-json\/wp\/v2\/arquitectura?post=48047"},{"taxonomy":"area","embeddable":true,"href":"https:\/\/becolve.com\/pt-pt\/wp-json\/wp\/v2\/area?post=48047"},{"taxonomy":"sector","embeddable":true,"href":"https:\/\/becolve.com\/pt-pt\/wp-json\/wp\/v2\/sector?post=48047"},{"taxonomy":"experto","embeddable":true,"href":"https:\/\/becolve.com\/pt-pt\/wp-json\/wp\/v2\/experto?post=48047"},{"taxonomy":"weborigen","embeddable":true,"href":"https:\/\/becolve.com\/pt-pt\/wp-json\/wp\/v2\/weborigen?post=48047"},{"taxonomy":"productos-tax","embeddable":true,"href":"https:\/\/becolve.com\/pt-pt\/wp-json\/wp\/v2\/productos-tax?post=48047"},{"taxonomy":"soluciones-tax","embeddable":true,"href":"https:\/\/becolve.com\/pt-pt\/wp-json\/wp\/v2\/soluciones-tax?post=48047"},{"taxonomy":"marcas-tax","embeddable":true,"href":"https:\/\/becolve.com\/pt-pt\/wp-json\/wp\/v2\/marcas-tax?post=48047"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/becolve.com\/pt-pt\/wp-json\/wp\/v2\/coauthors?post=48047"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}