REF:1180

IBH OPC UA Server/Client – 1180

Embedded OPC UA server/client for SIMATIC, Mitsubishi, and Rockwell controllers. The OPC UA Server/Client is configured using the free IBH OPC UA editor, the original Siemens STEP7, or the TIA Portal.

REF:1180

IBH OPC UA Server/Client – 1180

Embedded OPC UA server/client for SIMATIC, Mitsubishi, and Rockwell controllers. The OPC UA Server/Client is configured using the free IBH OPC UA editor, the original Siemens STEP7, or the TIA Portal.

IBHsoftec
Additional information
Protocols
  • OPC UA
  • RFC1006, ISO Over TCP
Port
  • Ethernet
Product family
  • IBHsoftec OPC Server
Description
Technical documentation

Embedded OPC UA server/client for SIMATIC, Mitsubishi, and Rockwell controllers.
The OPC UA Server/Client is configured using the free IBH OPC UA editor, the original Siemens STEP7, or the TIA Portal. No other special software is required. This allows the IBH OPC UA server/client to be perfectly integrated into the PLC project. The IBH OPC UA Server/Client can handle up to 31 STEP7 and/or TIA projects simultaneously.
The definition of the variables will be transferred from the programming tool to the IBH OPC UA Server/Client via Ethernet. The attributes of the variables (e.g., write protection or limits) will be defined directly within the PLC project. This allows symbolic access to variables and data block structures.
Communication with the S5 and S7 PLCs is established via Ethernet. If the PLC does not have an Ethernet port, our well-known IBH Link S7 or IBH Link S5 gateways can be used.
One of the advantages of the IBHsoftec solution is that IBH OPC UA supports both Client and Server functions simultaneously. This allows data exchange between different OPC UA servers. For example, control systems and other equipment with OPC UA servers from different manufacturers can exchange data with each other. The configuration of the client functions can be done using a standard web browser.
User-defined OPC UA variables: Data structures can be defined in a separate namespace and can be connected to any other OPC UA server via the client function. This means that other OPC UA clients can also read and write these data structures.
MQTT connection: User-defined OPC UA variables can be exchanged with an MQTT broker/server.
The IBH Link UA can thus be used as a layer between machines and control systems (MES, ERP…) independently of Simatic controllers.
While OPC Data Access allows access to real-time data, it supports OPC Historical Access, also called OPC HDA access, access to data already stored. From simple data logging systems to complex SCADA systems, historical data can be queried in a standardized manner. The activation of historical data is easily done via the web browser.

  • OPC UA server for easy connection to MES, ERP, and SAP systems and visualizations
  • OPC UA Client functions for data exchange between different OPC UA Servers
  • Integrated SoftPLC for data preprocessing
  • Scalable security levels through the exchange of digitally signed certificates
  • Connection to S7 PLC via S7 TCP/IP or IBH Link S7
  • Connection to PLC S5 via IBH Link S5
  • Convenient configuration with the new IBH OPC UA Editor, Siemens STEP7 or TIA Portal
  • Administration via web browser
  • Historical data
  • Alarms and conditions
  • Runs on Windows XP, Vista, Windows 7, Windows 8, Windows 10, Windows 11
  • Modbus connection
  • Custom and definable address space
  • Compatibility with SINUMERIK 840D/840D SL
  • NEW: Support for SINUMERIK ONE
  • Support for LOGO 8 and LOGO
  • Support for Mitsubishi robots, MELSEC IQR, FX5, QnA and L series controller
  • Compatibility with Rockwell Controllogix and Compactlogix controller
  • OPC UA via MQTT cloud connection

.

IBH OPC UA Server/Client – 1180