Ixxat CAN-CR100 – 1.01.0210.20000
CAN/CAN FD repeater with screw terminals and termination resistor
The Ixxat CAN-CR100 repeater with two CAN/CAN FD interfaces improves the load capacity of the CAN bus, establishes a physical coupling of the bus systems and offers galvanic isolation. It provides the flexibility to optimize network structures and frees them from the restrictions of the CAN bus structure for optimized operation. With integrated terminal resistors.
Ixxat CAN-CR100 – 1.01.0210.20000
CAN/CAN FD repeater with screw terminals and termination resistor
The Ixxat CAN-CR100 repeater with two CAN/CAN FD interfaces improves the load capacity of the CAN bus, establishes a physical coupling of the bus systems and offers galvanic isolation. It provides the flexibility to optimize network structures and frees them from the restrictions of the CAN bus structure for optimized operation. With integrated terminal resistors.
- Galvanic isolation
- CAN-Bus
- CAN-FD
- CANopen
- DeviceNet
- J1939
- CAN
- CAN-FD
- Field Bus
- IXXAT CAN repeaters
Robust industrial use
Designed for industrial environments, meeting high demands for robustness, temperature ranges, and safety.
Flexibility in CAN FD network design
Helps optimize CAN/CAN FD network structures by enabling extended designs (short lines, star and tree topologies).
Fast and transparent operation
Minimal impact on real-time behavior, equivalent to a short line length (approx. 35 m/175 ns delay). Allowing transparent transmission, compatible with all higher layer protocols.
Cost savings due to simple wiring
Optimized topologies allow for simpler wiring, resulting in fewer cables and cost savings in installation and maintenance.
Improved network reliability
Increased system reliability by electrically isolating CAN/CAN FD segments and feeding up to 1 kV.
Network monitoring and fault recovery
In the event of disturbances, the repeater automatically disconnects the affected segment and restores it after the fault is resolved.
Greater system protection
Using the CAN-CR100, network components can be galvanically isolated up to 1 kV. This reliably improves device protection against damage to the electronics caused by voltage peaks.
CAN and CAN FD interfaces combined in a single device
Equipped with two CAN/CAN FD channels, the repeater can be used in both CAN FD and CAN systems.
Integrated bus termination resistors
Integrated bus termination resistors (120 Ohm, switchable via DIP switch) prevent reflections at the line ends and ensure optimal communication.