Ixxat CAN-CR300 – 1.01.0210.40200
Four-channel CAN/CAN FD repeater
The Ixxat CAN-CR300 repeater with four CAN/CAN FD interfaces improves the load capacity of the CAN bus, establishes a physical coupling of the bus systems, and offers galvanic isolation. It provides the flexibility to optimize network structures and frees them from the restrictions of the CAN bus structure for optimized operation.
Ixxat CAN-CR300 – 1.01.0210.40200
Four-channel CAN/CAN FD repeater
The Ixxat CAN-CR300 repeater with four CAN/CAN FD interfaces improves the load capacity of the CAN bus, establishes a physical coupling of the bus systems, and offers galvanic isolation. It provides the flexibility to optimize network structures and frees them from the restrictions of the CAN bus structure for optimized operation.
- Galvanic isolation
- CAN-Bus
- CAN-FD
- CANopen
- DeviceNet
- J1939
- CAN
- CAN-FD
- IXXAT CAN repeaters
Robust industrial use
Designed for industrial environments, meeting high demands for robustness, temperature ranges, and safety.
Flexibility in CAN FD network design
Helps optimize CAN/CAN FD network structures by enabling extended designs (short lines, star and tree topologies).
Fast and transparent operation
Minimal impact on real-time behavior, equivalent to a short line length (approx. 35 m/175 ns delay). Allowing transparent transmission, compatible with all higher layer protocols.
Cost savings due to simple wiring
Optimized topologies allow for simpler wiring, resulting in fewer cables and cost savings in installation and maintenance.
Improved network reliability
The CAN-CR300 ensures system reliability by electrically isolating CAN/CAN FD segments and power, automatically separating network faults, and maintaining network operation.
Improved network monitoring and fault recovery
In the event of disturbances on the CAN lines, the repeater automatically disconnects the affected segment and resets it once the fault is resolved, ensuring uninterrupted network operation.
Greater system protection
Using the CAN-CR300, network components can be galvanically isolated up to 1 kV. This reliably improves device protection against damage to electronics caused by voltage spikes.
CAN and CAN FD interfaces combined in a single device
Equipped with four CAN/CAN FD channels, the CAN-CR300 can be used to establish physical coupling and galvanic isolation of two segments of CAN and CAN FD bus systems.
Related products
Looking for more information about this product?
Complete the form, and we’ll contact you.


