DALI-2 to Modbus TCP & RTU Server Application with 1 DALI Channel – In703dal0640000

DALI to BACnet/IP or BACnet MS/TP - 1 DALI channel
Integrates any DALI/DALI-2 controller and DALI-2 input devices such as light or occupancy sensors with a BACnet BMS or any BACnet/IP or BACnet MS/TP controller. This integration aims to make DALI devices and their data and resources accessible from a BACnet-based control system or device as if they were part of the BACnet system and vice versa.

REF:IN703DAL0640000

DALI-2 to Modbus TCP & RTU Server Application with 1 DALI Channel – In703dal0640000

DALI to BACnet/IP or BACnet MS/TP - 1 DALI channel
Integrates any DALI/DALI-2 controller and DALI-2 input devices such as light or occupancy sensors with a BACnet BMS or any BACnet/IP or BACnet MS/TP controller. This integration aims to make DALI devices and their data and resources accessible from a BACnet-based control system or device as if they were part of the BACnet system and vice versa.

HMS Networks
Additional information
Field Bus
  • Modbus (RTU and Plus)
Protocols
  • Dali
Port
  • Ethernet
  • Field Bus
  • Industrial Ethernet
  • RS232
  • RS485
  • Serial
Description
Technical documentation

BACnet Compatibility

The gateway is BTL certified and supports BACnet/IP and BACnet MS/TP protocols.

Advanced BACnet functions

Advanced BACnet functions, such as calendars, trend logs, schedules and more, are available.

DALI Compatibility

The gateway is DALI-2 certified and supports DALI/DALI-2 controllers and DALI-2 input devices: push buttons, absolute input devices, and occupancy and light sensors.

Easy start-up/integration of DALI with Intesis MAPS

DALI integration and commissioning processes are managed through the Intesis MAPS configuration tool. Templates can be imported and reused as many times as necessary, significantly reducing commissioning time.

Local control options

Occupancy and light sensors, push buttons, and absolute inputs can be controlled locally from the gateway. The DALI standard device type for Energy and Diagnostics data has also been implemented.

Color control

RGB and tunable white controls are available in Intesis MAPS to meet the demand for human-centric lighting.

Maximum 64 drivers/ballasts + 64 DALI-2 input devices

Supports up to 64 drivers/ballasts + 64 DALI-2 input devices (sensors/push buttons/absolute inputs).

Signals and power

DALI power supply integrated into the gateway, so no external power supply is required. Up to 10,000 signals can be defined in total, with a guaranteed output current of 230 mA.